Provides a 21st century solution for Kenall wall-mount fluorescent tube-technology in Wall Mount Correctional Luminaries with an energy efficient, high performance 18 Watt LED retrofit
The U.S.-manufactured ActiveLED® Kenall Retrofit is an innovative, self-contained LED light engine designed to easily replace the inefficient, high-wattage fluorescent tubes and ballasts in jail and prison applications for most Kenall wall-mount fixtures, providing energy savings of 50-80 percent.
Correctional Facilities, Jails and Prisons use Kenall style luminaires for illuminating the offender's cell or other holding spaces. The 30" and 50" Wall-Mount fixtures typically have fluorescent tubes and one or two ballasts that need regular maintenance.
The existing tubes and ballasts can be retrofitted with the low-wattage ActiveLED Retrofit engine and the Kenall fixtures still have the same robust characteristics. The only noticeable difference in its outward appearance is a better quality of light, which improves the safety of its surroundings.
Ringdale’s patented LED technology also ensures a long life span of 90,000 hours (24/7 is 8,760 hours per year), lowering the bottom line when it comes to maintenance and operational costs.
The ActiveLED "Kenall" Light Retrofit meets many commercial, residential and municipalities’ latest sustainability mandates for reducing energy usage and contains zero mercury.
ActiveLED® Kenall Retrofit Product Overview
Ringdale provides five models of ActiveLED Kenall Retrofits for Kenall 24" and 48" Wall-Mount Correctional Facility lighting applications:
Product Code |
Application |
CCT Color |
Wattage |
Light Output |
Power Supplies |
2705-5518-R |
Kenall 50"fixture |
5000K |
18 Watts |
~2,900 Lumens |
2 |
2705-4018-R |
Kenall 50"fixture |
4000K |
18 Watts |
~2,000 Lumens |
1 |
2705-3518-R |
Kenall 50"fixture |
3500K |
18 Watts |
~1,900 Lumens |
1 |
2703-3018-R |
Kenall 30"fixture |
3000K |
18 Watts |
~1,900 Lumens |
1 |
2703-2718-R |
Kenall 30"fixture |
2700K |
18 Watts |
~1,900 Lumens |
1 |
ActiveLED® Technology
Ringdale uses the latest in energy efficient LEDs and LED Modules producing equal or greater light output than current FL, CFL or HID technology (Metal Halide and High Pressure Sodium). Our state-of-the-art electronics monitor current and temperature of the LED substrate to assure maximum performance under the prevailing environmental conditions and a Lumen Lifetime of 90,000 hours (90% Luminous Flux).
ActiveLED® Warranties
We provide mechanically robust indoor and outdoor lighting systems; our warranties are 10 years on LED elements, fixtures and drivers / power supplies / drivers.
Ringdale is an ISO 9001:2015 company. Ringdale provides products of the highest quality designed and manufactured in Texas, USA and in the United Kingdom.
Removing Existing Lamp & Electronics Assembly from existing Kenall Luminaire
It is a very straightforward process to remove the existing Kenall Luminaire electronics assembly in preparation for installing the ActiveLED BKenall Retrofit, as described below.
Before starting any disassembly / assembly work, first disconnect the AC power from the existing Wall-Mount Luminaire.
• | Remove Cover / Diffuser from existing Kenall fixture by undoing the security screws (details may vary slightly based on the model of Luminaire). Retain screws for reassembly of Cover. |
• | Remove existing Kenall electronics complete with Lamp, Lamp Holder and Ballast Electronics from the fixture and dispose of in accordance with local regulations. |
• | Attach the ActiveLED Retrofit assembly to the existing Kenall fixture using the existing mounting holes. |
• | Connect the existing AC cabling to the ActiveLED Kenall retrofit Power Supply. |
• | Carefully attach the ActiveLED Retrofit LED assembly to the Kennal Retrofit Backplate (6 machine screws) and connect the DC cable from the ActiveLEDs to the power supply (2-wire snap-on connector). |
• | Apply AC power to verify that the installation is correct and the ActiveLED Retrofit is illuminated, reattach Cover/ Diffuser using existing screws. |
NOTE: Kenall luminaire housing and diffuser are not included in the ActiveLED retrofit price. ActiveLED also makes complete vandal resistant and correctional facility fixtures for details click here
Input Voltage: | • Universal Voltage 100..277V 50/60Hz • Excellent performance with Generators in Brownouts and Voltage Surges • Optional Surge Protection Device (SPD) available |
---|---|
Power Stastics: | 18 Watt LEDs, 20 Watt Fixtures |
Power Factor: | ~ 0.95 |
Listings & Tests | cUL Listed Driver, suitable for damp locations. TM21 based on CALIPER ISTM Test to UL1598 CALIPER LM-79 Report, LM-80 info available CE File, RoHS compliant, IP66 Rated. Conforms to FCC Part 15.19 Subpart B Class A |
Operating Temperature: | -58° F to +149° F (-50° C to +65° C) |
Dimensions: Weight: | 24" / 48" wide depending on type, to fit 30" or 50" fixtures. |
Retrofit Contents: | • Retrofit Wallmount Backplate Assy c/w Power Supply / Driver • Retrofit LED Assy and assorted machine screws |
CCT Color Temperatures: | 2700K, 3000K, 3500K, 4000K or 5000K in accordance with ANSI C78.377A |
Caution! All specifications published herein are subject to change without notice. See website ActiveLED.com for Terms and Conditions of use of the website and the information provided herein. See Ringdale website on www.ringdale-technology.com for Terms and Condtions of Sale and Service.