Provides a 21st century solution for Bega model FS wall-mount 15" diameter lamp-technology Wall Sconces with an energy efficient, high performance 20 Watt LED retrofit
The U.S.-manufactured ActiveLED® Bega Retrofit is an innovative, self-contained LED light engine designed to easily replace the inefficient, high-wattage light lamp assembly in most Bega FS wall-mount fixtures, providing energy savings of 50-80 percent.
Commercial offices, hospitals, libraries, municipalities, universities and colleges use Bega style luminaires for illuminating and accenting hallways, corridors, stairways, atriums and indoor public spaces. The Bega FS is a dome-shaped wall sconce that typically has incandescent, compact fluorescent or metal halide lamps and ballasts that need regular maintenance.
The existing lamps can be retrofitted with the low-wattage ActiveLED BegaRetrofit engine and the Bega fixtures still have the same aesthetically-pleasing characteristics. The only noticeable difference in its outward appearance is a better quality of light, which improves the safety value of its surroundings.
Ringdale’s patented LED technology also ensures a long life span of 90,000 hours (24/7 is 8,760 hours per year), lowering the bottom line when it comes to maintenance and operational costs.
The ActiveLED "Bega" Light Retrofit meets many commercial, residential and municipalities’ latest sustainability mandates for reducing energy usage and contains zero mercury.
ActiveLED® Bega Retrofit Product Overview
Ringdale provides five models of ActiveLED Bega Retrofits for Bega FS 15" Wall Sconces for different lighting applications:
Product Code |
Application |
CCT Color |
Wattage |
Light Output |
AFIT-C32-N50R18WH |
Bega FS fixture |
5000K |
20 Watt |
~1,820 lm |
AFIT-C32-N40R18WH |
Bega FS fixture |
4000K |
20 Watt |
~1,690 lm |
AFIT-C32-N35R18WH |
Bega FS fixture |
3500K |
20 Watt |
~1,560 lm |
AFIT-C32-N30R18WH |
Bega FS fixture |
3000K |
20 Watt |
~1,480 lm |
AFIT-C32-N27R18WH |
Bega FS fixture |
2700K |
20 Watt |
~1,390 lm |
ActiveLED® Technology
Ringdale uses the latest in energy efficient LEDs and LED Modules producing equal or greater light output than current CFL or HID technology (Metal Halide and High Pressure Sodium). Our state-of-the-art electronics monitor current and temperature of the LED substrate to assure maximum performance under the prevailing environmental conditions and a Lumen Lifetime of 90,000 hours (90% Luminous Flux).
ActiveLED® Warranties
We provide mechanically robust indoor and outdoor lighting systems; our warranties are 10 years on LED elements, fixtures and drivers / power supplies / drivers.
Ringdale is an ISO 9001:2015 company. Ringdale provides products of the highest quality designed and manufactured in Texas, USA and in the United Kingdom.
Removing Existing Lamp & Electronics Assembly from Bega FS Luminaire
It is a very straightforward process to remove the existing Bega FS Luminaire electronics assembly in preparation for installing the ActiveLED Bega Retrofit, as described below.
Before starting any disassembly / assembly work, first disconnect the AC power from the existing Wall-Mount Luminaire.
• | Remove Bezel and Glass Dome from existing Bega fixture by undoing two or three machine screws (details may vary slightly based on the model of Luminaire). Retain screws for reassembly of Bezel. |
• | Remove existing Bega fixture complete with Lamp, Lamp Holder and Ballast Electronics from the building and dispose of in accordance with local regulations. |
• | Attach the ActiveLED Retrofit Backplate assembly to the building structure using the existing mounting holes. |
• | Connect the existing AC cabling to the ActiveLED Bega retrofit Power Supply. |
• | Carefully attach the ActiveLED Retrofit LED assembly to the Bega Retrofit Backplate (3 machine screws) and connect the DC cable from the ActiveLEDs to the power supply (2-wire snap-on connector). |
• | Apply AC power to verify that the installation is correct and the ActiveLED Retrofit is illuminated, reattach Bezel / Glass Dome using existing screws. |
Illustration of ActiveLED® Bega LED Retrofit
The following illustrates how the two main parts of the ActiveLED Bega Retrofit are assembled / installed and how the existing Bega FS front cover (Bezel) and Lens (Glass Dome) are attached to the Retrofit. The picture is of ActiveLED Bega Retrofits installed at the IBM campus in Austin, Texas:
NOTE: Bega bezel and glass are not included in the ActiveLED retrofit price.
ActiveLED® Bega Retrofit Part Numbers:
AFIT-C32-N50R18WH, CCT5000K
AFIT-C32-N40R18WH, CCT4000K
AFIT-C32-N35R18WH, CCT3500K
AFIT-C32-N30R18WH, CCT3000K
AFIT-C32-N27R18WH, CCT2700K
Input Voltage: | • 100 .. 277 VAC, • 50/60 Hz. • Digital Power Source, dedicated circuit breaker or • SPD-3 surge protector strongly recommended |
---|---|
Power Stastics: | 18 Watt LEDs, 20 Watt Fixtures |
Power Factor: | ~ 0.95 |
Listings & Tests | cUL Listed Driver, suitable for damp locations. TM21 based on CALIPER ISTM Test to UL1598 CALIPER LM-79 Report, LM-80 info available CE File, RoHS compliant, IP66 Rated. Conforms to FCC Part 15.19 Subpart B Class A |
Operating Temperature: | -58° F to +149° F (-50° C to +65° C) |
Dimensions: Weight: | 15" outer diameter x 2.65" deep (34.93 x 16.70 cm) 2.2 lbs (1.0 Kg) |
Retrofit Contents: | • Retrofit Wallmount Backplate Assy c/w Power Supply / Driver • Retrofit LED Assy and assorted machine screws |
CCT Color Temperatures: | 2700K, 3000K, 3500K, 4000K or 5000K in accordance with ANSI C78.377A |
Caution! All specifications published herein are subject to change without notice. See website ActiveLED.com for Terms and Conditions of use of the website and the information provided herein. See Ringdale website on www.ringdale-technology.com for Terms and Condtions of Sale and Service.
+1-833-850-7097 | |
+44 (0)844 264 1570 |