ActiveLED®  Battery Fuel Gauge


  • ActiveLED® Battery Fuel Gauge with automatic shut-off for LiFePO4 or Lead Acid battery banks

  • Low ON resistance of 3.5mOhm max at high current

  • Programmable low battery warning

  • Programmable Chemistry - Lead Acid or LiFePO4

  • Supports 24..100V Systems

  • Cascading EDSaP communication ports for ActiveLED's Building Automation System

  • LED indicator for operational (more than 3 minutes / 3 minutes or less / safety shut-off activated)

  • 0..100A loads with a total loss of <0.7% at 50A

    Low standby power consumption of < 0.3 Watts



ActiveLED® Battery Fuel Gauge with automatic shut-off for LiFePO4 or Lead Acid battery banks

Extends the life of Battery Banks by protecting them from being over-charged or depleted below specified levels.

More than 90% of battery bank failures have their root cause in unhealthy depletion of the batteries at one time in the system's life. The investment in an ActiveLED® Battery Fuel Gauge and Shutoff can completely eliminate the risk of total or unhealthy battery depletion.

State-of-the-art technology puts the actual energy loss for the benefit of protection at less than 0.8% at full load. Minimal loss is a key requirement for alternative energy fed systems.

3.5 mOhm ON-resistance low voltage shut-off for 24 to 100 V DC battery banks.

The device monitors low battery voltage and turns the battery bank completely off when critical voltage is reached. This protects the battery which is the most expensive component in any DC system.

The device has a default program for 16 cell Lithium Iron Phosphate (LiFePO4) and for 24 cell Lead Acid batteries. It can be monitored using ActiveLED's EDSaP signaling and protocol as well as programmed for any number of cells not exceeding 100 Volts.

At 48V with a 100A load the internal loss of the device is only 35 watts making the total loss in operation less than 0.8% at full load and less than 0.7% at half load.

ActiveLED® Similar Products

ActiveLED's line of Solar Controllers are highly efficient, reliable, and maintenance free.



Description
Part Number
48V (16 cell) LiFePO
00-27-1694-0048-LO-48/16

24V (16 cell) LiFePO
00-27-1694-0024-LO-24/8

48V (24 cell) Lead Acid
00-27-1694-0048-LA-48/24

24V (12 cell) Lead Acid
00-27-1694-0048-LA-24/12


Technical Information

Bus Voltage:0-100V

Battery Voltage:0-100V

ON Resistance:3.5mOhm @ 100A

LED Indicator:Green, Yellow, Red

I2C Bus:Extender Bus

Caution! All specifications published herein are subject to change without notice. See website ActiveLED.com for Terms and Conditions of use of the website and the information provided herein. See Ringdale website on www.ringdale-technology.com for Terms and Condtions of Sale and Service.

+1-833-850-7097